 Agentless Management Service and iLO Channel Interface Driver
 for iLO Firmware 1.45 or higher
  (for VMware ESXi 6.0)
======================================================================
 [Software name   ] Agentless Management Service (600.11.4.5)
                    iLO Channel Interface Driver (600.10.1.0)
 [Registered name ]
    esxi6.0uX-mgmt-bundle-3.4.5-8.zip
 [Copyright (C)   ] Hewlett Packard Enterprise
 [Supported server models]
                 - Express5800/R120h-1M
                 - Express5800/R120h-2M
                 - Express5800/R120h-1E
                 - Express5800/R120h-2E
                 - Express5800/T120h
 [Supported users ] All users who use the servers above and iLO 
                    Firmware 1.45 or higher with the VMware ESXi 
                    below installed.
                    - VMware ESXi 6.0 Update 3 or later
 [Software type   ] Utility
 [Format ] zip
======================================================================

[Software Introduction]
Agentless Management Service and iLO Channel Interface Driver 
(hereinafter called "this software") is a module required to get 
information of Host OS via iLO on the VMware ESXi 6 or later 
virtualized platform.

Carefully read the following user license agreement for NEC software
before using this software. 
If you do not agree to the terms of the agreement, do not download this 
software. By downloading this software, you agree to be bound by the 
terms of the agreement.

[User license agreement for NEC software] 
This user license agreement is an agreement between you and NEC
Corporation (hereinafter called "NEC"). 
Under the following terms of this agreement, NEC grants you the right
to use the software program (hereinafter called "licensed program"),
and you are to agree to the terms. You are to take any responsibility
for the selection of, installation of , use of, or results from the
use of, the licensed program.

1. Term and termination

(1) This user license agreement is effective from the date you receive
    this software product.
(2) You may terminate it under this license agreement at any time by
    giving NEC a written notice no less than one month prior to the
    date you wish to do so.
(3) NEC may terminate your right to use the licensed program at any
    time, if you fail to comply with the terms of this user license
    agreement.
(4) Your right to use the licensed program continues to exist until
    it is terminated in accordance with the provisions of this user
    license agreement. 
(5) Immediately upon termination of your right to use the licensed
    program, all of your other rights under this user license
    agreement will terminate. You must destroy the licensed program,
    all copies thereof, and related documents (e.g., manuals) provided
    with the licensed program immediately upon termination of your
    right to use the licensed program. 

2. Use right 
(1) You may use the licensed program only on NEC Express5800 series
    servers in which the following VMware ESXi is installed.
    - VMware ESXi 6.0 update 3 or later

3. Copy, modify, or merge copies of the licensed program 
(1) You may make a single copy of the licensed program only for your
    backup purpose in case of the licensed program data loss or
    corruption; provided, however, that this does not apply to the
    case where the licensed program is installed in a fixed memory.
    In this case, you may make a single copy of the licensed program
    only for your backup and storage puropose in case of loss or
    corruption of the storage medium of the licensed program.
(2) You must display the copyright and other proprietary rights
    notices that appear on and in the licensed program on all copies
    of the licensed program. 
(3) Unless otherwise specified in this user license agreement, you may
    not use, copy, modify, or merge copies of the licensed program,
    publish or distribute any information contained in or materials of
    the licensed program in publications or through networks, or make
    your own decision on handling it in any other way. 
(4) You may not copy the related documents (e.g., manuals) provided
    with the licensed program or publish them in publications or
    through networks under any circumstances. 
(5) This user license agreement does not transfer the intangible
    property rights associated with the licensed program to you. 

4. Transfer to third party
(1) You may transfer all of your rights under this user license
    agreement to a third party, provided that all of the following
    conditions are satisfied: 
(a) You transfer this user license agreement, the licensed program
    all copies of the licensed program,, and all related documents
    (e.g., manuals) provided with the licensed program to the third
    party, and retain none of them. 
(b) The transferee agrees to the terms of this user license agreement.
(2) Unless otherwise specified in this user license agreement, you may
    not rent or lease the use right in the Licensed Software, transfer
    the licensed program to the third party, transport the licensed
    program, or make your own decision on handling it in any other way.

5. Decompilation 
 You may not carry out reverse engineering of, decompile, or disassemble
 the licensed program.

6. Warranty
(1) NEC does not provide any guarantee for the licensed program. You
    are liable to pay for all cost arising from problems as a result
    of the use of the licensed program. 
(2) Irrespective of the term (1), when NEC corrects licensed-program
    errors (bugs), NEC may, at its discretion, provide an error-corrected
    program, a program for correction (hereinafter called a modification
    program), or information for correction by an NEC-decided method.
    The modification program provided to you is regarded as the licensed
    program. 

7. Limitation of liability 
 NEC assumes no liability for your lost profit, damages arising from
 special circumstances (including damages which NEC can or could foresee),
 or damages claimed to you by any third party.

8. Others 
 Disputes over this user license agreement are to be settled at the
 Tokyo District Court as the exclusively agreed competent court.


----------------------------------------------------------------------
[Setup Procedure]

[Prerequisite]
   (1) Check the iLO firmware version by the following way.

      [How to check the version of iLO firmware]
      - Server Health Summary
        Push the UID button on the server and check the version of 
        the iLO firmware on the screen.
        (For the detail, refer to Server Health Summary in iLO5 user guide.)
      - Remote
        Check the version of the iLO firmware on 
        "Firmware & OS Software - Installed Firmware"
        by iLO web interface.

      If the version of iLO firmware is earlier than 1.45,
      proceed to the next step.
      If the version of iLO firmware is 1.45 or higher, refer to 
      [Update Procedure].

   (2) Update FW by the latest Starter Pack. 
       Please refer to Download on the following URL or purchase 
       the optional Starter Pack. 
       
       -> Related Links : Download
          -> Documents & Software
             -> Rack or Tower: (Select your server model)

[Update Procedure]
  (1) Select [Troubleshooting Options] from the direct console. Enable
      ESXi Shell access from SSH or the direct console, and log
      into ESXi Shell as a user with administrator rights. (To log into
      ESXi shell from the direct console, press [Alt] + [F1].)

  (2) Execute the following command to check whether the previous
      version is already installed.
      If the line starting with "amsd" or "ilo" is
      displayed, previous one is already installed. Proceed to the next
      step.
      If nothing is displayed, refer to [Installation Procedure] for
      fresh installation.
        # esxcli software vib list | grep -i amsd 
        # esxcli software vib list | grep -i ilo

  (3) Uninstall the previous version by following 
      [Uninstallation Procedure] for previous one.

  (4) Install the new version by following 
      [Installation Procedure] below.

[Installation Procedure]
  (1) Copy zip file to the client terminal where vSphere Client is 
      installed. 

  (2) Start vSphere Client. Connect to ESXi as a user with administrator
      rights and enter the Maintenance Mode.  
      To switch ESXi to maintenance mode, connect to ESXi with vSphere
      Client, right-click the ESXi icon in the inventory, and select
      [Enter Maintenance Mode]. 

  (3) Select the ESXi icon in the inventory and click the [Configuration]
      tab.

  (4) Select [Storage] in [Hardware] to display a list of datastores. 
      Right-click the datastore to which you are going to upload the
      zip file and select [Browse Datastore]. 

  (5) The datastore browser will appear. 
      Click [Create New folder] from the toolbar to create a "zip"
      folder.

  (6) Click the [Upload] icon from the toolbar and select [Upload File].

  (7) When an item upload window appears, select the zip file and then
      click [Open]. 

  (8) If a warning dialog box for upload/download appears, select [Yes].

  (9) When the [Uploading] dialog box disappears, upload is completed.

 (10) Select [Troubleshooting Options] from the direct console. Enable
      ESXi Shell access from SSH or the direct console, and log
      into ESXi Shell as a user with administrator rights. (To log into
      ESXi shell from the direct console, press [Alt] + [F1].)

 (11) Execute the following command to install Agentless Management 
      Service and iLO Channel Interface Driver for VMware ESXi:
         # esxcli software vib install -n amsd -d [Path]esxi6.0uX-mgmt-bundle-3.4.5-8.zip
         # esxcli software vib install -n ilo -d [Path]esxi6.0uX-mgmt-bundle-3.4.5-8.zip
      In [Path], specify an absolute path as below.
         /vmfs/volumes/datastore1/zip/

      Once the provider installation is complete, the following message
      will appear. 
        Installation Result
           Message: The update completed successfully, but the system needs to be rebooted for the changes to be effective.
           Reboot Required: true
           VIBs Installed: [Package Name]
           VIBs Removed:
           VIBs Skipped:

 (12) Execute the reboot command to restart the server.

 (13) Log into ESXi Shell and execute the following command to
      check that amsd and ilo have been successfully installed.
        # esxcli software vib list | less

 (14) Delete the uploaded zip file and then log out from ESXi Shell.
      (If you logged into ESXi Shell from the direct console, execute
      the exit command and then press [Alt] + [F2].)

 (15) Select [Troubleshooting Options] from the direct console and then
      return the ESXi Shell access settings to their original values.
      Also connect to ESXi from vSphere Client or VMware Host Client,
      and then exit maintenance mode. 


[Uninstallation Procedure]
  (1) Start vSphere Client. Connect to ESXi as a user with administrator
      rights and enter the Maintenance Mode.  
      To switch ESXi to maintenance mode, connect to ESXi with vSphere
      Client, right-click the ESXi icon in the inventory, and select
      [Enter Maintenance Mode].

  (2) Select [Troubleshooting Options] from the direct console. Enable
      ESXi Shell access from SSH or the direct console, and the log
      into ESXi Shell as a user with administrator rights. (To log into ESXi
      shell from the direct console, press [Alt] + [F1].)

  (3) Execute the following command to uninstall Agentless Management 
      Service and iLO Channel Interface Driver for VMware ESXi.
        # esxcli software vib remove -n amsd
        # esxcli software vib remove -n ilo

  (4) Execute the reboot command to restart the server.

  (5) Select [Troubleshooting Options] from the direct console and then
      return the ESXi Shell access settings to their original values.
      Also connect to ESXi from vSphere Client or VMware Host Client,
      and then exit maintenance mode. 

----------------------------------------------------------------------
[Attached Files]
   Length      Date    Time    Name
 ---------  ---------- -----   ----
  16250485  07-30-2019 06:51   esxi6.0uX-mgmt-bundle-3.4.5-8.zip

You can check the integrity of the downloaded file by comparing the 
following values in the md5sum column and the MD5 checksums of the file
you have downloaded. If the checksums do not match, it means an error 
occurred during download.

 md5sum                          | Filename
---------------------------------+------------------------------
a20f99c9617ed193eb180cf8768d6dae  esxi6.0uX-mgmt-bundle-3.4.5-8.zip

- esxi6.0uX-mgmt-bundle-3.4.5-8.zip (for VMware ESXi 6.0)
  * Install just as zip file. You do not have to unzip.

   Length      Date    Time    Name
 ---------  ---------- -----   ----
      339  07-29-2019 11:41   index.xml
      237  07-29-2019 11:41   vendor-index.xml
     8176  07-29-2019 11:41   metadata-esxi6.0uX-mgmt-bundle-3.4.5-8.zip
  4069650  07-29-2019 11:41   fc-enablement-600.3.4.0.10-2494585.vib
  8515176  07-29-2019 11:41   smx-provider-600.03.15.00.2-2768847.vib
    13522  07-29-2019 11:41   ilo_600.10.1.0.12-1OEM.600.0.0.2494585.vib
    13872  07-29-2019 11:41   cru_6.0.9.8-1OEM.600.0.0.2494585.vib
  3936530  07-29-2019 11:41   amsd-600.11.4.5-18.2494585.vib
---------                     -------
 16557502                     8 files

----------------------------------------------------------------------
[Revision History]
  2019/11/15
  "Enhancement"  600.11.4.5 / 600.10.1.0
    Updated for the new FW released on 2019/11.
  2019/04/02
  "Enhancement"  600.11.4.0 / 600.10.1.0
    Updated for the new FW released on 2019/04.
  2019/02/18
  "Enhancement"  600.11.3.6 / 600.10.1.0
    Updated for the new FW released on 2019/02.
  2018/09/18
  "Enhancement"  600.11.3.0 / 600.10.1.0
    Updated for the new FW released on 2018/09.
  2018/03/09
  "Enhancement"  600.11.2.0 / 600.10.1.0
    Updated for the new FW released on 2018/03.
  2017/12/15
  "Enhancement"  600.11.1.5 / 600.10.1.0
     1. Additional support of the applicable model
      - Express5800/R120h-1E
      - Express5800/R120h-2E
      - Express5800/T120h

  2017/11/28  600.11.1.5 / 600.10.1.0
  First version released.

----------------------------------------------------------------------
[Trademarks and Copyright]

The copyright for this software is held by Hewlett Packard Enterprise. 
NEC is permitted to distribute this software by Hewlett Packard 
Enterprise. 
* VMware is a registered trademark of VMware, Inc. in the United States
  and/or other jurisdictions.
* All other company and product names in this document are the registered 
  trademarks or trademarks of their respective owners.
----------------------------------------------------------------------
   Copyright NEC Corporation 2017-2019