BMC firmware 00.16, SDR 00.10
=========================================================================================================
Software name     :  Express5800/R120d-1M, Express5800/R120d-2M
                     BMC firmware update module for offline
Models            :  Express5800/R120d-1M, Express5800/R120d-2M
Software revisions:  See below
Type of software  :  BMC firmware
---------------------------------------------------------------------------------------------------------


[ About the software ]

  The Express5800/R120d-1M, Express5800/R120d-2M BMC firmware and SDR update module ("the software")
  supports the following functional enhancement in the Express5800/R120d-1M, Express5800/R120d-2M
  models:

   - Improved Web server function of EXPRESSSCOPE Engine 3 and changed the description of the online
     help.
   - Changed to reboot management LAN port if management LAN port does not receive any packet for a
     certain period of time.
   - Support the RETINA Security Scan.
   - Changed the limit of input character to 64 characters when creating the CSR in SSL configuration.
   - Fixed the issue to be not able to use "." character in the host name when creating a CSR in SSL
     configuration.
   - Changed the sel behavior. Clear all sel entry immediately if the sel configuration is changed from
     "Stop logging SEL" to "Clear all SEL" when the sel repository is full.
   - Fixed the issue that a negative value does not displayed correctly in the "Component"-"temperature"
     of EXPRESSSCOPE Engine 3.
   - Improved character-based remote console of EXPRESSSCOPE Engine 3 to enable to display during
     POST/expansion of option ROM.
   - Changed to enable the user who logged in with operator user level to execute nmidump via command
     line interface of EXPRESSSCOPE Engine 3.
   - Improved the issue that active directry user who belongs multiple group may be aborted to log in
     EXPRESSSCOPE Engine 3.
   - Improve the character-based remote console via command line interface  of EXPRESSSCOPE Engine 3
     to be enabled to accept mass input for example to copy and paste long text.
   - Improved the issue that the network functinon of EXPRESSSCOPE Engine 3 become unavailable by
     receiving Jumbo Frame Packet from Management LAN port.
   - Improved the internal user configuration for  EXPRESSSCOPE Engine 3 to be disabled to change.
   - Improved cooling function to support N8103-152 RAID Controller (1GB,RAID0/1/5/6).(SDR)


  Note:
  - To prevent a system failure, please read this document carefully and follow the procedure for
    successful update.  Should your system malfunctions or is powered off due to an unplanned event
    during update (for example, power blackout or cutoff, lightening, and noise), the system may be
    damaged and fails to operate normally.  In this case, any remedial measures shall be taken at your
    expense.

   The following items are note for customers using the server which installed [N8115-04]
   Remote KVM and Media License

  - This software does not support to update the BMC firmware and SDR by Remote Media on
    EXPRESSSCOPE Engine 3.


[ Models and software revisions to update ]

  Users who use the following server models and BMC firmware versions need update:

   - Models to update: 

     1. Express5800/R120d-1M
     2. Express5800/R120d-2M

   - BMC firmware and SDR versions to update:

        - BMC firmware
                          BMC Firmware Revision:  00.13
                          BMC Firmware Revision:  00.14

        - SDR
                          SDR Revision:           00.09


  NOTE:
    If your BMC firmware version is later than the above, you do not require the update
    (the latest versions already include the functions to be added by the software).

   - How to confirm your BMC Firmware and SDR version:

     Please make sure to confirm proper BMC Firmware and SDR version by any of the following means.(*1)

     * How to confirm by the server which will be updated *

     - By ESRAS Utility, to confirm your BMC Firmware and SDR version:

     (1)  Run the ESRAS Utility.
     (2)  Select the [Intelligent Platform Management Interface] sub menu.

     Confirmation of BMC Firmware version

     (3)  Select the [Management controller information] sub menu.
     (4)  Select the [Basbrd Mgmt Ctlr] sub menu.
     (5)  The BMC firmware version of your system will be displayed.

     Confirmation of SDR version

     (6)  Select the [Repository Information] sub menu and press the Enter key.
     (7)  The SDR version of your system will be displayed.


     - By BIOS Setup, to confirm your BMC Firmware and SDR version:

     (1)  Power on the system.
     (2)  When the following message appears, press the F2 key to start the BIOS Setup Menu.

                              "Press <F2> to enter SETUP"

     (3)  Using the arrow keys, move the cursor to [Server]. 
     (4)  Select the [System Management] sub menu and press the Enter key. 
     (5)  The software versions of your system will be displayed. 
     (6)  After confirmation of the software versions, press the ESC key and exit the [System Management]
          sub menu.
     (7)  Move the cursor to [Exit], using the arrow keys. 
     (8)  Select [Exit Discarding Changes], and exit the BIOS Setup Menu. 


     * How to confirm by the remote access *

     - By ESMPRO Manager Ver.5, to confirm your BMC Firmware and SDR version:

     (1)  Run ESMPRO Manager Ver.5.
     (2)  After selecting the server, select the [Remote Control] tab.
     (3)  Select the [IPMI Information] sub menu.

     Confirmation of BMC Firmware version

     (4)  Select the [MC(Management Controller) Information] sub menu.
     (5)  Select the [Basbrd Mgmt Ctlr] sub menu.
     (6)  The BMC firmware version of your system will be displayed.

     Confirmation of SDR version

     (7)  Select the [SDR-Management Information] sub menu and press the Enter key.
     (8)  The SDR version of your system will be displayed.


     - By EXPRESSSCOPE Engine 3, to confirm your BMC Firmware and SDR version:

     (1)  Run EXPRESSSCOPE Engine 3.
     (2)  Select the [system] tab.
     (3)  Select the [IPMI information] sub menu.

     Confirmation of BMC Firmware version

     (4)  Select the [MC] button and select [basbrd Mgmt Ctrl].
     (5)  Check [Firmware Revision].

     Confirmation of SDR version

     (6)  Select the [SDR] button and select LAST Record ID / Record Type : OEMSDR
     (7)  Check [[OEM Data] SDR Version].


Please read the following User License Agreement ("Agreement") carefully.
If you do not agree to the terms and conditions of this Agreement, you shall not download the Software.
Downloading the Software indicates your acceptance of the terms and conditions of the Agreement.

[User License Agreement]

NEC Corporation ("NEC") grants you the right to use the software program ("Software") under the terms
and conditions of this Agreement only in the country in which you acquired the Software. You shall
agree to all provisions of this Agreement and assume responsibility for selection, installation, use 
and effect of the Software purchased for your desired effect.

The Software uses the software ("GPL Module") granted by GNU General Public License("GPL") or GNU 
Lesser General Public License("LGPL"). This Agreement does not cover GPL Module.

The Software includes the following GPL Module and LGPL Module.

         <GPL Module>
           grep
           kbd
           procps
           libsepol
           pcmcia-cs
           initscripts
           SysVinit
           module-init-tools
           mingetty
           samba-client
           gdb
           bogl-bterm
           gpm
           slang
           syslinux
           libpci2
           BusyBox
           dmidecode
           memtester
           cachetester
           ethtool
           TeDoLiF product

        <LGPL Module>
           glibc
           libtermcap
           glibc-common
           libusb
           alsa-lib
           newt


You can distribute or change the module based on the conditions of GPL or LGPL or any later Version,
stipulated by Free Software Foundation. The module is supposed to be useful, however, NEC does not 
guarantee it.
In addition, NEC does not release any copyright of GPL Module, designed by NEC.

   == notice ==
   The Free Software Foundation (FSF) is a non-profit corporation to support the spread of
   the free software.
   You need to refer to The Free Software Foundation ( http://www.fsf.org/ )for details of
   GNU General Public License Version 2 and GNU Lesser General Public License.

You shall agree that NEC does not answer to any questions regarding the GPL Module.
By using the Software including GPL Module, you will be bounded by the terms stipulated in GPL and LGPL.
 
The following Agreement is applicable to the Software excluding GPL Module aforesaid.

<Agreement for the Software>

1. Terms 
1.1 This Agreement shall come into force on the date of your receipt of the Software.
1.2 You may terminate the license granted hereunder by notifying us in writing at least one month
    prior to the desired termination date.
1.3 NEC may terminate the license granted you hereunder at any time if you fail to comply with any
    terms and conditions of this Agreement. 
1.4 The license to the Software shall remain in force until the license is terminated on the date
    set forth hereunder. 
1.5 Upon termination of the license, other rights granted you hereunder shall also be terminated.
    You must destroy or dispose of the Software, any copies of the Software and manual and other
    materials provided with the Software. 

2. Copyright 
2.1 The Software shall solely be used in the NEC Express5800 servers.
2.2 NEC grants you the right to use the Software only in the country in which you acquired the 
    Software in accordance with the conditions of the preceding paragraph.

3. Copying, altering, and combining of the Software
3.1 You may only make one copy of the Software solely for a backup purpose,
    provided, however, that the copy of the Software is loaded into permanent memory of the system.
    You may store the Software solely to prevent damages or loss of the memory media.
3.2 You shall place the copyright notice and other legends on each copy of the Software.
3.3 You may not use, copy, alter, combine, publish, reproduce the Software over the Internet, or
    otherwise dispose of the Software except as provided in this Agreement. 
3.4 You may not copy, publish the manual or other related documentation provided with the Software,
    or reproduce such manual and documentation over the Internet.
3.5 No intangible property right to the Software shall be transferred to you.

4. Transfer
4.1 You may assign your rights granted hereunder to a third party only if all conditions below are
    satisfied: 
    a. You shall assign and shall not retain this Agreement, the Software, allcopies of the
    Software, or the manual or other related documentationprovided with the Software. 
    b. The transferee agrees to this Agreement.
4.2 You shall not sublicense, assign, transfer, or otherwise dispose of the Software or the right of
    use to any third party except as provided herein.

5. Reverse compile
   You may not reverse engineer, decompile, or otherwise disassemble the Software.

6. Limitation of warranties
6.1 The Software is provided "as is" without warranty of any kind. In no event shall NEC be liable
    with respect to any claim by you on account of or arising out of the use of the Software.
6.2 Notwithstanding the provisions of the preceding paragraph, in case NEC makes any bug-fix version
    to the Software, NEC will, at its expense, furnish you with such bug-fix version, update version,
    or information in relation to such bug-fix or update version both in the source code form and
    object code form, and such bug-fix version or update version shall be considered as the licensed
    Software.

7. No liability 
    In no event shall NEC be liable for any indirect or consequential damages or loss of profit or 
    damages based on any third party claim, even if NEC has been advised of the possibility of such
    damages. 


[ Installation procedures ]

Perform the following steps to extract the Software and update your BMC firmware.

- How to extract:

(1) Download update module to a desired directory.
(2) Extract downloaded module to a desired directory.
(3) The software and its installation procedures (readme file) will be extracted to that specified
    folder.
    The folder has "B14S1005B0O.iso" and "READMEE.txt".

- How to update:

(1) Perform the steps of the readme file to create a CD-R from the image file, then to update the BMC
    firmware using the CD-R.


---------------------------------------------------------------------------------------------------------
[ Revision history ]

2012/10/26 BMCFW Revision 00.16, SDR Revision 00.10
   - Improved Web server function of EXPRESSSCOPE Engine 3 and changed the description of the online
     help.
   - Changed to reboot management LAN port if management LAN port does not receive any packet for a
     certain period of time.
   - Support the RETINA Security Scan.
   - Changed the limit of input character to 64 characters when creating the CSR in SSL configuration.
   - Fixed the issue to be not able to use "." character in the host name when creating a CSR in SSL
     configuration.
   - Changed the sel behavior. Clear all sel entry immediately if the sel configuration is changed from
     "Stop logging SEL" to "Clear all SEL" when the sel repository is full.
   - Fixed the issue that a negative value does not displayed correctly in the "Component"-"temperature"
     of EXPRESSSCOPE Engine 3.
   - Improved character-based remote console of EXPRESSSCOPE Engine 3 to enable to display during
     POST/expansion of option ROM.
   - Changed to enable the user who logged in with operator user level to execute nmidump via command
     line interface of EXPRESSSCOPE Engine 3.
   - Improved the issue that active directry user who belongs multiple group may be aborted to log in
     EXPRESSSCOPE Engine 3.
   - Improve the character-based remote console via command line interface  of EXPRESSSCOPE Engine 3
     to be enabled to accept mass input for example to copy and paste long text.
   - Improved the issue that the network functinon of EXPRESSSCOPE Engine 3 become unavailable by
     receiving Jumbo Frame Packet from Management LAN port.
   - Improved the internal user configuration for  EXPRESSSCOPE Engine 3 to be disabled to change.
   - Improved cooling function to support N8103-152 RAID Controller (1GB,RAID0/1/5/6).(SDR)


2012/04/24 BMCFW Revision 00.14, SDR Revision 00.09
   - Fixed the issue that the configuration of access log is not initialized even if the BMC is
     initialized by using the BMC configuration function.
   - Fixed the issue that old log might be rarely displayed by executing BMC Reset after clearing
     access log.


2012/04/06 BMCFW Revision 00.13, SDR Revision 00.09
   - Initial Release.


---------------------------------------------------------------------------------------------------------
[ Legal notices (trademarks and copyrights) ]

   All contents on this software are the copyright of NEC Corporation or the third-party software
   developer.

   EXPRESSSCOPE is a registered trademark of NEC Corporation.

   Microsoft, Windows, Windows Vista and Windows Server are registered trademarks of Microsoft
   Corporation in the United States and other countries.

   Linux is a trademark or registered trademark of Linus Torvalds in the United States and
   other countries.

   This software uses the software under GNU General Public License or GNU Lesser General Public License.

   All other product, brand, or trade names used in this publication are the trademarks or registered
   trademarks of their respective trademark owners.


---------------------------------------------------------------------------------------------------------
   Copyright NEC Corporation 2012