*************************************************
 NEC ESMPRO Manager Update
*************************************************

[Introduction]

This update is for NEC ESMPRO Manager.

Target versions:
    NEC ESMPRO Manager Ver6.65 and Ver7.21


[NEC ESMPRO Manager version after applying the update]

The version does not change after applying the update.


[How to apply the update]

 1) Log onto the server as a user with administrative privileges.

 2) Run the following update program.

   Select the following batch file in Windows Explorer,
   and run it by clicking the 'Run as administrator' option
   on the right click mouse button menu.

      Update.bat

    * To run the batch file from a command prompt,
      right-click the 'command prompt' option on the [Start] menu,
      and open the command prompt by clicking the 'Run as
      administrator' option on the menu shown.

 3) Finish update

   The effect of the update will become effective immediately.
   If you see the message "Restart the system to enable the update",
   restart the system.


[How to check the result of applying the update]

 Verify that the following files are replaced.

 * According to the Windows operating system being used,
   check files under either of the following folders.

    NVBASE\\BIN
      File name                             Date              Size
     -------------------------------------------------------------------------
      MwaLm.dll                             2024/01/15 12:06  135,168

    ESMWEB\wbserver\webapps\esmpro\WEB-INF\service\imlmonitoring
      File name                             Date              Size
     -------------------------------------------------------------------------
      ImlAlert.txt                          2024/01/05 16:39  430,143

    ESMWEB\wbserver\webapps\esmpro\WEB-INF\classes\com\nec\jp\dianascope\alert\receiver\analyze
      File name                             Date              Size
     -------------------------------------------------------------------------
      NvBaseAnalyzer.class                  2024/01/31 09:55    5,071

    ESMWEB\wbserver\webapps\esmpro\WEB-INF\classes\com\nec\jp\dianascope\alert\receiver
      File name                             Date              Size
     -------------------------------------------------------------------------
      NvbaseAlertReceiveThread.class        2024/01/31 09:55    8,977

    ESMWEB\wbserver\webapps\esmpro\WEB-INF\classes\com\nec\jp\dianascope\alert\receiver\analyze\esmrequest
      File name                             Date              Size
     -------------------------------------------------------------------------
      AlertAnalyzeRequestFactory.class      2024/01/31 09:55    2,250
      NvBaseAnalyzeRequest.class            2024/01/31 09:55    4,153

    ESMWEB\wbserver\webapps\esmpro\WEB-INF\classes\com\nec\jp\dianascope\alert\receiver\nvbase
      File name                             Date              Size
     -------------------------------------------------------------------------
      NvbaseLogAccessor$1.class             2024/01/31 09:55    1,042
      NvbaseLogAccessor$2.class             2024/01/31 09:55      722
      NvbaseLogAccessor.class               2024/01/31 09:55   17,774
      ReportStatusMonitoringManager.class   2024/01/31 09:55   15,293


    According to the result (success or failure),
    one of the following exit codes (%errorlevel%) is returned.

     Code | Description
    ------+---------------------------------------------
       0  | Successful completion.
       1  | Not the target version of this UPDATE.
       2  | An error occurred during stopping service.
    ------+---------------------------------------------


[Notes]
 1) A version confirmation procedure of NEC ESMPRO Manager is as follows.
    Click [NEC ESMPRO] in [NEC ESMPRO Manager] under [all programs
    (program)] from [Start] menu.
    Please confirm the current version on the 'Manager' tab.

 2) The log of this update is %AppData%\SM_YYYYMMDD-HHMM.log.
    YYYYMMDD-HHMM is date and time of run the update.