*************************************************
NEC ESMPRO Manager Update
*************************************************
[Introduction]
This update is for NEC ESMPRO Manager.
Target versions:
NEC ESMPRO Manager Ver6.65 and Ver7.21
[NEC ESMPRO Manager version after applying the update]
The version does not change after applying the update.
[How to apply the update]
1) Log onto the server as a user with administrative privileges.
2) Run the following update program.
Select the following batch file in Windows Explorer,
and run it by clicking the 'Run as administrator' option
on the right click mouse button menu.
Update.bat
* To run the batch file from a command prompt,
right-click the 'command prompt' option on the [Start] menu,
and open the command prompt by clicking the 'Run as
administrator' option on the menu shown.
3) Finish update
The effect of the update will become effective immediately.
If you see the message "Restart the system to enable the update",
restart the system.
[How to check the result of applying the update]
Verify that the following files are replaced.
* According to the Windows operating system being used,
check files under either of the following folders.
NVBASE\\BIN
File name Date Size
-------------------------------------------------------------------------
MwaLm.dll 2024/01/15 12:06 135,168
ESMWEB\wbserver\webapps\esmpro\WEB-INF\service\imlmonitoring
File name Date Size
-------------------------------------------------------------------------
ImlAlert.txt 2024/01/05 16:39 430,143
ESMWEB\wbserver\webapps\esmpro\WEB-INF\classes\com\nec\jp\dianascope\alert\receiver\analyze
File name Date Size
-------------------------------------------------------------------------
NvBaseAnalyzer.class 2024/01/31 09:55 5,071
ESMWEB\wbserver\webapps\esmpro\WEB-INF\classes\com\nec\jp\dianascope\alert\receiver
File name Date Size
-------------------------------------------------------------------------
NvbaseAlertReceiveThread.class 2024/01/31 09:55 8,977
ESMWEB\wbserver\webapps\esmpro\WEB-INF\classes\com\nec\jp\dianascope\alert\receiver\analyze\esmrequest
File name Date Size
-------------------------------------------------------------------------
AlertAnalyzeRequestFactory.class 2024/01/31 09:55 2,250
NvBaseAnalyzeRequest.class 2024/01/31 09:55 4,153
ESMWEB\wbserver\webapps\esmpro\WEB-INF\classes\com\nec\jp\dianascope\alert\receiver\nvbase
File name Date Size
-------------------------------------------------------------------------
NvbaseLogAccessor$1.class 2024/01/31 09:55 1,042
NvbaseLogAccessor$2.class 2024/01/31 09:55 722
NvbaseLogAccessor.class 2024/01/31 09:55 17,774
ReportStatusMonitoringManager.class 2024/01/31 09:55 15,293
According to the result (success or failure),
one of the following exit codes (%errorlevel%) is returned.
Code | Description
------+---------------------------------------------
0 | Successful completion.
1 | Not the target version of this UPDATE.
2 | An error occurred during stopping service.
------+---------------------------------------------
[Notes]
1) A version confirmation procedure of NEC ESMPRO Manager is as follows.
Click [NEC ESMPRO] in [NEC ESMPRO Manager] under [all programs
(program)] from [Start] menu.
Please confirm the current version on the 'Manager' tab.
2) The log of this update is %AppData%\SM_YYYYMMDD-HHMM.log.
YYYYMMDD-HHMM is date and time of run the update.